LANmark-OF UC Outdoor LSZH 2-24core APAC Region

Products

LANmark-OF UC LSZH 12core OM3 Black

Nexans ref. N175.475

  • Packaging: m (1000m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 12
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 12core OM4 Black

Nexans ref. N177.475

  • Packaging: m (1000m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 12
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 12core SM G.652.D Black

Nexans ref. N174.475

  • Packaging: m (1000m)
  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 12
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 24core OM3 Black

Nexans ref. N175.481

  • Packaging: m (1000m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 24
  • Outer Diameter: 10.6 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 212.0 mm
  • Minimum static operating bending radius: 106 mm

 

LANmark-OF UC LSZH 24core OM4 Black

Nexans ref. N177.481

  • Packaging: m (1000m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 24
  • Outer Diameter: 10.6 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 212.0 mm
  • Minimum static operating bending radius: 106 mm

 

LANmark-OF UC LSZH 24core SM G.652.D Black

Nexans ref. N174.481

  • Packaging: m (1000m)
  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 24
  • Outer Diameter: 10.6 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 212.0 mm
  • Minimum static operating bending radius: 106 mm

 

LANmark-OF UC LSZH 2core OM3 Black

Nexans ref. N175.470

  • Packaging: m (1000m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 2
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 2core OM4 Black

Nexans ref. N177.470

  • Packaging: m (1000m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 2
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 2core SM G.652.D Black

Nexans ref. N174.470

  • Packaging: m (1000m)
  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 2
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 4core OM3 Black

Nexans ref. N175.471

  • Packaging: m (1000m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 4
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 4core OM4 Black

Nexans ref. N177.471

  • Packaging: m (1000m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 4
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 4core SM G.652.D Black

Nexans ref. N174.471

  • Packaging: m (1000m)
  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 4
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 6core OM3 Black

Nexans ref. N175.472

  • Packaging: m (1000m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 6
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 1000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 6core OM4 Black

Nexans ref. N177.472

  • Packaging: m (1000m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 6
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 6core SM G.652.D Black

Nexans ref. N174.472

  • Packaging: m (1000m)
  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 6
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 8core OM3 Black

Nexans ref. N175.473

  • Packaging: m (1000m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 8
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 8core OM4 Black

Nexans ref. N177.473

  • Packaging: m (1000m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 8
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

LANmark-OF UC LSZH 8core SM G.652.D Black

Nexans ref. N174.473

  • Packaging: m (1000m)
  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 8
  • Outer Diameter: 9.3 mm
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 186.0 mm
  • Minimum static operating bending radius: 93 mm

 

Description

Description

Standards

  • International
    IEC 60332-1; IEC 60332-3 Cat.C; IEC 60793-2-10; ISO/IEC 11801
  • National
    ANSI/TIA-568-C.3

Description and Application
 

Nexans LANmark-OF UC fibre cable is designed for outdoor applications. The construction is suitable for use outdoor for direct burial. It consists of a Unitube structure protected by corrugated steel tape armouring, the Unitube can hold up to 24C fibres. This provides rodent protection and high crush resistance. The cable has a LSZH outer jacket.

Construction
  
Legend accompanying the cross section drawing:

  1. Optical fibres (250 um)
  2. Waterproof gel filling
  3. Loose tube
  4. Glass Yarn
  5. Corrugated steel tape armour
  6. LSZH outer jacket with UV resistant additive 

 
Characteristics
 

  • Flame retardant (IEC 60332-1) and fire retardant (IEC 60332-3-24)
  • Designed for termination by splicing
  • Central loose tube design
  • Corrugated steel protection
  • Waterproof structure and UV-resistant
  • Available in Multimode and Singlemode fibre
  • Available from 2-24 fibres

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Armour type
Corrugated steel
Outer sheath
LSZH
Sheath colour
Black

Mechanical characteristics

Mechanical characteristics

Maximum pulling force (IEC 60794-1-2-E1)
1300 N

Usage characteristics

Usage characteristics

Ambient installation temperature, range
0 - 40 °C
Operating temperature, range
-20 - 60 °C
Storage temperature, range
-30 - 60 °C

Resources

Resources

Documentation

xlsx — 0 B
xlsx — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close