LANmark-OF UC Outdoor PE 2-24core APAC Region

Products

LANmark-OF UC PE 12core OM3 Black APAC Region

Nexans ref. N175.185

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 12
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 12core OM4 Black APAC Region

Nexans ref. N177.185

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 12
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 12core SM G.652.D Black APAC Region

Nexans ref. N174.185

  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 12
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4):
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 24core OM3 Black APAC Region

Nexans ref. N175.191

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 24
  • Outer Diameter: 9.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 184.0 mm
  • Minimum static operating bending radius: 92 mm

 

LANmark-OF UC PE 24core OM4 Black APAC Region

Nexans ref. N177.191

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 24
  • Outer Diameter: 9.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 184.0 mm
  • Minimum static operating bending radius: 92 mm

 

LANmark-OF UC PE 24core SM G.652.D Black APAC Region

Nexans ref. N174.191

  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 24
  • Outer Diameter: 9.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 184.0 mm
  • Minimum static operating bending radius: 92 mm

 

LANmark-OF UC PE 2core OM3 Black APAC Region

Nexans ref. N175.180

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 2
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 2core OM4 Black APAC Region

Nexans ref. N177.180

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 2
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 2core SM G.652.D Black APAC Region

Nexans ref. N174.180

  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 2
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 4core OM3 Black APAC Region

Nexans ref. N175.181

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 4
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 4core OM4 Black APAC Region

Nexans ref. N177.181

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 4
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 4core SM G.652.D Black APAC Region

Nexans ref. N174.181

  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 4
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 6core OM3 Black APAC Region

Nexans ref. N175.182

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 6
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 6core OM4 Black APAC Region

Nexans ref. N177.182

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 6
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 6core SM G.652.D Black APAC Region

Nexans ref. N174.182

  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 6
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 8core OM3 Black APAC Region

Nexans ref. N175.183

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 8
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 8core OM4 Black APAC Region

Nexans ref. N177.183

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 8
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

LANmark-OF UC PE 8core SM G.652.D Black APAC Region

Nexans ref. N174.183

  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 8
  • Outer Diameter: 8.2 mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 164.0 mm
  • Minimum static operating bending radius: 82 mm

 

Description

Description

Standards

  • International
    IEC 60793-2-10; ISO/IEC 11801
  • National
    ANSI/TIA-568-C.3

Description and Application
 

Nexans LANmark-OF UC fibre cable is designed for outdoor applications. The construction is suitable for use outdoor for direct burial. It consists of a Unitube structure protected by corrugated steel tape armouring, the Unitube can hold up to 24C fibres. This provides rodent protection and high crush resistance. The cable has a HDPE outer jacket.

Construction
  
Legend accompanying the cross section drawing:

  1. Optical fibres (250 um)
  2. Waterproof gel filling
  3. Loose tube
  4. Glass Yarn
  5. Corrugated steel tape armour
  6. HDPE outer jacket with UV resistant additive 

Characteristics

  • Designed for termination by splicing
  • Central loose tube design
  • Corrugated steel protection
  • Waterproof structure and UV-resistant
  • Available in Multimode and Singlemode fibre
  • Available from 2-24 fibres

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Armour type
Galvanized steel tapes
Outer sheath
HDPE
Sheath colour
Black

Mechanical characteristics

Mechanical characteristics

Crush resistance (IEC 60794-1-E3)
300 N/cm
Maximum pulling force (IEC 60794-1-2-E1)
1300 N

Usage characteristics

Usage characteristics

Ambient installation temperature, range
0 - 40 °C
Operating temperature, range
-20 - 60 °C
Storage temperature, range
-30 - 60 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close