2XSY 12/20 KV - IEC

Products

CU/XLP/PVC 20 1X 50/16

Nexans ref. 13000100

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Phase Conductor Cross Section: 50 mm²
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 26.0 mm

 

CU/XLP/PVC 20 1X 50/25

Nexans ref. 13005173

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Phase Conductor Cross Section: 50 mm²
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 26.0 mm

 

CU/XLP/PVC 20 1X 70/16

Nexans ref. 13000101

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²
  • Phase Conductor Cross Section: 70 mm²
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 28.0 mm

 

CU/XLP/PVC 20 1X 70/25

Nexans ref. 13005174

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²
  • Phase Conductor Cross Section: 70 mm²
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 28.0 mm

 

CU/XLP/PVC 20 1X 95/16

Nexans ref. 13000102

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Phase Conductor Cross Section: 95 mm²
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 30.0 mm

 

CU/XLP/PVC 20 1X 95/25

Nexans ref. 13005175

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Phase Conductor Cross Section: 95 mm²
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 30.0 mm

 

CU/XLP/PVC 20 1X120/16

Nexans ref. 13000103

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Phase Conductor Cross Section: 120 mm²
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 31.0 mm

 

CU/XLP/PVC 20 1X120/25

Nexans ref. 13005176

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Phase Conductor Cross Section: 120 mm²
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 31.0 mm

 

CU/XLP/PVC 20 1X150/16

Nexans ref. 13000610

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Phase Conductor Cross Section: 150 mm²
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 32.0 mm

 

CU/XLP/PVC 20 1X150/25

Nexans ref. 13005177

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Phase Conductor Cross Section: 150 mm²
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 32.0 mm

 

CU/XLP/PVC 20 1X185/16

Nexans ref. 13004536

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Phase Conductor Cross Section: 185 mm²
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 34.0 mm

 

CU/XLP/PVC 20 1X185/25

Nexans ref. 13000104

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Phase Conductor Cross Section: 185 mm²
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 34.0 mm

 

CU/XLP/PVC 20 1X240/25

Nexans ref. 13000105

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Phase Conductor Cross Section: 240 mm²
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 36.5 mm

 

Description

Description

Standards

  • International
    IEC 60332-1-2; IEC 60502-2

Electric cable with stranded copper conductor, conductor screen of semiconducting compound, XLPE insulation, insulation screen of semiconducting compound, copper wires metallic screen, PVC outer sheath. Rated voltage 12/20 kV (Um=24kV)

 

Note: on request the cables are available with copper helix tape above the copper wires metallic screen and/or with water protection of metallic screen

 

Application

in grounds, outdoors, indoors and in cable ducts

 

Note: on request the cables are available with Polyethylene outer sheath (2XS2Y) or with Low Smoke Zero Halogen (LSZH) outer sheath (2XSH).

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor flexibility
Stranded class 2
Conductor shape
Circular
Material of the inner semi-conductor
Semi-conducting compound
Insulation
XLPE
Material of the external semi-conductor
Semi-conducting compound
Screen
Copper wire
Outer sheath
PVC

Dimensional characteristics

Dimensional characteristics

Number of cores
1
Nominal insulation thickness
5.5 mm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
12 / 20 (24) kV

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close