FLAMEX® MULTIFUNCTION VEHICLE BUS (MVB) 120 Ω

Products

2PK596

Nexans ref. 2PK596

  • Packaging: Cut to length (m)
  • Construction type: 2 x 0.50²
  • Core identification: Black, White
  • Nominal outer diameter: 8.0 mm
  • Approximate weight: 84 kg/km
  • Minimum operating temperature: -25 °C

 

2PF580

Nexans ref. 2PF580

  • Packaging: Cut to length (m)
  • Construction type: 2 x 0.50²
  • Core identification: Black, White
  • Nominal outer diameter: 8.0 mm
  • Approximate weight: 84 kg/km
  • Minimum operating temperature: -40 °C

 

MVB 4 x 0,50

Nexans ref. 2PE993

  • Packaging: Cut to length (m)
  • Construction type: 4 x 0.50²
  • Core identification: White/Yellow + Red/Black
  • Nominal outer diameter: 8.0 mm
  • Approximate weight: 86 kg/km
  • Minimum operating temperature: -25 °C

 

2PK697

Nexans ref. 2PK697

  • Packaging: Cut to length (m)
  • Construction type: 4 x 0.50²
  • Core identification: White/Yellow + Red/Black
  • Nominal outer diameter: 8.0 mm
  • Approximate weight: 86 kg/km
  • Minimum operating temperature: -40 °C

 

MVB 4 x AWG 22/19

Nexans ref. 45903050

  • Packaging: Cut to length (m)
  • Construction type: 4 x AWG 20/19
  • Core identification: White/Yellow + Red/Black
  • Nominal outer diameter: 7.9 mm
  • Approximate weight: 91 kg/km
  • Minimum operating temperature: -40 °C

 

Description

Description

Standards

  • International
    EN 45545-2 (HL3)

 

Nexans develops halogen-free communication cables for higher transmission performances to address emerging applications.

FLAMEX® communication cables are conform to EN 45545-2, easy to pool, quick to connect and compatible with standard connectors, and designed to improve the protection against electrical disturbances, electromagnetic noises. Nexans experience in the design of shielding technology enables us to propose all constructions with high EMC protection. All these features make FLAMEX® cables the best candidate for new built and retrofit works.

 

FIRE SAFETY

FLAMEX® MVB cables are conform to EN 45545-2 HL3

 

GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: ... x outer cable diameter
    • For installation and occasional movements: ... x outer cable diameter

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Type of cable
MVB
Conductor material
Tin plated copper
Sheath colour
Turquoise
Outer sheath
EPR
Halogen free
EN 50267-2-1 & EN 60684-2

Usage characteristics

Usage characteristics

Flame retardant
EN 45545-2 (HL3)
Fire retardant
IEC 60332-3-25
Smoke density
EN 45545-2 (HL3)
Gases toxicity
EN 50305-9.2
Electro magnetic interference resistance
Yes
Chemical resistance
Good

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close