FLAMEX® EN 50382-2 FXZ
FLAMEX® EN 50382-2 FXZ
Reinforced sheathed high temperature extra flexible Power cables
Read moreFLAMEX DTREN150028 EN 50382-2 3600V 300 FXZ 120°C
Nexans ref. 10282755
- Packaging: Cut to length (1000m)
- Conductor cross-section: 300 mm²
FLAMEX DTREN150028 EN50382 3600V 240 FXZ 120°C
Nexans ref. 10232560
- Packaging: Cut to length (1000m)
- Conductor cross-section: 240 mm²
FLAMEX DTREN150028 EN50382 3600V 25 FXZ 120°C
Nexans ref. 10261352
- Packaging: Cut to length (1000m)
- Conductor cross-section: 25 mm²
FLAMEX DTREN150028 EN50382 3600V 35 FXZ 120°C
Nexans ref. 10265651
- Packaging: Cut to length (1000m)
- Conductor cross-section: 35 mm²
FLAMEX DTREN150028 EN50382 3600V 6 FXZ 120°C
Nexans ref. 10265735
- Packaging: Cut to length (1000m)
- Conductor cross-section: 6 mm²
FLAMEX EN 50382-2 3600V 120 FXZ 120°C
Nexans ref. 10211477
- Packaging: Cut to length (1000m)
- Conductor cross-section: 120 mm²
FLAMEX EN 50382-2 3600V 150 FXZ 120°C
Nexans ref. 10211478
- Packaging: Cut to length (1000m)
- Conductor cross-section: 150 mm²
FLAMEX EN 50382-2 3600V 185 FXZ 120°C
Nexans ref. 10200535
- Packaging: Cut to length (1000m)
- Conductor cross-section: 185 mm²
FLAMEX EN 50382-2 3600V 50 FXZ 120°C
Nexans ref. 10211475
- Packaging: Cut to length (1000m)
- Conductor cross-section: 50 mm²
FLAMEX EN 50382-2 3600V 70 FXZ 120°C
Nexans ref. 10211476
- Packaging: Cut to length (1000m)
- Conductor cross-section: 70 mm²
FLAMEX EN 50382-2 3600V 95 FXZ 120°C
Nexans ref. 10202387
- Packaging: Cut to length (1000m)
- Conductor cross-section: 95 mm²
Description
Description
Standards
-
InternationalEN 45545-2 (HL3); EN 50382-2
Application
These specific extra flexible cables with mechanical reinforced insulation are dedicated to be used as jumper.
Construction
- Conductor
Extra Flexible class 6 copper according to IEC 60228
* tinned copper for 120°C Class
* plain copper for 150°C Class - Separator
Unweaved tape - Insulation
Cross-linked silicone type EI 111, according to EN 50382-1 with an embedded polyester reinforcement.
Colour : black outer layer
Marking
FLAMEX SI - EN 50382-2 - 3600 V - cross-section mm² - FXZ - class temperature (120°C) - NEXANS 279 - week/year or
FLAMEX SI - DTREN 150028 - EN 50382-2 - 3600 V - cross-section mm² - FXZ - class temperature (120°C) - NEXANS 279 - week/year
Guide to use
Cabling rules are given according to EN 50343
- Minimum bending radius (static) : 4 x outer cable diameter
- Minimum bending radius (dynamic) : 6 x outer cable diameter
- Pulling tensible force (dynamic) during installation : 50 N/mm² of copper size
- Mechanical (static) tensible force : 15N/mm² of copper size
- Permissible current carrying capacities : value and calculation method are given in EN 50355
Standards
Construction according to EN 50382-2
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania