TFR-CV 6/10kV
TFR-CV 6/10kV 1x 16mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 16 mm²
- Outer Diameter: 20 mm
- Approximate weight: 470 kg/km
TFR-CV 6/10kV 1x 25mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 25 mm²
- Outer Diameter: 21 mm
- Approximate weight: 680 kg/km
TFR-CV 6/10kV 1x 35mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 35 mm²
- Outer Diameter: 22 mm
- Approximate weight: 690 kg/km
TFR-CV 6/10kV 1x 50mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 50 mm²
- Outer Diameter: 23 mm
- Approximate weight: 850 kg/km
TFR-CV 6/10kV 1x 70mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 70 mm²
- Outer Diameter: 25 mm
- Approximate weight: 1100 kg/km
TFR-CV 6/10kV 1x 95mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 95 mm²
- Outer Diameter: 27 mm
- Approximate weight: 1390 kg/km
TFR-CV 6/10kV 1x 120mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 120 mm²
- Outer Diameter: 28 mm
- Approximate weight: 1680 kg/km
TFR-CV 6/10kV 1x 150mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 150 mm²
- Outer Diameter: 30 mm
- Approximate weight: 1670 kg/km
TFR-CV 6/10kV 1x 185mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 185 mm²
- Outer Diameter: 32 mm
- Approximate weight: 2360 kg/km
TFR-CV 6/10kV 1x 240mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 240 mm²
- Outer Diameter: 35 mm
- Approximate weight: 3020 kg/km
TFR-CV 6/10kV 1x 300mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 300 mm²
- Outer Diameter: 37 mm
- Approximate weight: 3640 kg/km
TFR-CV 6/10kV 1x 400mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 400 mm²
- Outer Diameter: 40 mm
- Approximate weight: 4510 kg/km
TFR-CV 6/10kV 1x 500mm²
Nexans ref.
- Colour: Natural
- Number of cores: 1
- Conductor cross-section: 500 mm²
- Outer Diameter: 43 mm
- Approximate weight: 5650 kg/km
TFR-CV 6/10kV 3x 16mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 16 mm²
- Outer Diameter: 39 mm
- Approximate weight: 1510 kg/km
TFR-CV 6/10kV 3x 25mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 25 mm²
- Outer Diameter: 41 mm
- Approximate weight: 1945 kg/km
TFR-CV 6/10kV 3x 35mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 35 mm²
- Outer Diameter: 43 mm
- Approximate weight: 2330 kg/km
TFR-CV 6/10kV 3x 50mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 50 mm²
- Outer Diameter: 46 mm
- Approximate weight: 2810 kg/km
TFR-CV 6/10kV 3x 70mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 70 mm²
- Outer Diameter: 50 mm
- Approximate weight: 3620 kg/km
TFR-CV 6/10kV 3x 95mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 95 mm²
- Outer Diameter: 53 mm
- Approximate weight: 4545 kg/km
TFR-CV 6/10kV 3x 120mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 120 mm²
- Outer Diameter: 57 mm
- Approximate weight: 5680 kg/km
TFR-CV 6/10kV 3x 150mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 150 mm²
- Outer Diameter: 60 mm
- Approximate weight: 6410 kg/km
TFR-CV 6/10kV 3x 185mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 185 mm²
- Outer Diameter: 64 mm
- Approximate weight: 7700 kg/km
TFR-CV 6/10kV 3x 240mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 240 mm²
- Outer Diameter: 69 mm
- Approximate weight: 9915 kg/km
TFR-CV 6/10kV 3x 300mm²
Nexans ref.
- Colour: White / Black / Red
- Number of cores: 3
- Conductor cross-section: 300 mm²
- Outer Diameter: 74 mm
- Approximate weight: 12920 kg/km
Description
Description
Standards
-
NationalKS C IEC 60502-2; KWS 413
Application
Power cable for residential, commercial building and distribution circuit.
The flame retardant cable for tray conformed to the standard (for technique of electrical equipment)
1. Conductor: Stranded annealed round plain copper, Class 2
2. Conductor screen: Extruded semi-conductive compound or taping
3. Insulation: Cross-linked Polyethylene (XLPE).
4. Insulation screen:
5. Shield: Copper tape
6. Unit: Cabling circular shielded solid wire in case of more 3 cores
7. Outer sheath: Black Flame retardant PVC (TFR PVC)
Colors
1 core : Natural color (XLPE)
3 cores: Black, White, Red
TFR-CV 6/10kV design
| ##image:56003## |
Inner Semi-conductive material Insulation Outer Semi-Conductive material Shield Binder Tape Outer Sheath(FR PVC)
|
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Fire safety characteristics
Fire safety characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania